- Evidence item
- For Evidence item, identify one inspectable record: the 32-piece QP-14 sample record from M03-I01 (F04), seven-reading bore summary from M03-I02 (F05), gauge calibration record from M03-I03 (F06), or correlation record sought because of M03-I04 (F07). Name its date/identifier and trace fields, marking absent details “Not supplied.” Do not call a summary raw data. Review: supplier-quality and metrology reviewers.
- Supplied value
- For Supplied value, transcribe the smallest decision-relevant fact supported by the cited module input and preserve its supplied confidence or uncertainty. Cite M03-I02 (F05); if insufficient, mark “Not supplied” and name the missing bounded evidence. Never convert a report, allegation, estimate, or provisional statement into a verified fact. Keep pending for the quality owner and any required specialist.
- Units or tolerance
- For Units or tolerance, copy the supplied unit and controlled tolerance without recomputing them: M03-I02 (F05) supplies millimeters and 24.00 ± 0.05 mm. Mark method, uncertainty, or any other tolerance “Not supplied” unless separately evidenced. Do not use the 32-piece sample count in M03-I01 (F04) as a unit or tolerance. Escalate to authorized quality and engineering reviewers for requirement interpretation.
- Source input ID
- Source input ID: List the exact module input ID beside every material statement, adding its fact ID when present. Cite M03-I01 (F04), M03-I02 (F05), M03-I03 (F06); if insufficient, mark “Not supplied” and name the missing citation trace. Do not cite the case brief as approval or cite an input that does not support the statement. Review: the quality owner and any required specialist.
- Evidence-validity issue
- For Evidence-validity issue, state the calibration and correlation limitations exactly: M03-I03 (F06) places the gauge two days beyond its due date, and M03-I04 (F07) says no documented correlation to the in-calibration alternative exists. Mark instrument identity and any validity conclusion “Not supplied.” Do not substitute the second gauge retrospectively or declare measurements valid or invalid. Keep pending for authorized quality and metrology review.
- Missing raw or trace fields
- State the exact absent record, decision, method, value, or authority; explain why it matters and the bounded next request for Missing raw or trace fields. Evidence: M03-I02 (F05), M03-I03 (F06); mark “Not supplied” when absent. Do not hide the gap in narrative, fill it with a placeholder value, or imply the request was answered. Escalate to the quality owner and any required specialist.
- Permitted inference
- Permitted inference: State the narrow inference the evidence permits and the adjacent conclusion it does not permit, keeping observation, measurement validity, cause, and disposition separate. No “Evaluate measurement evidence” source fact supplies it; mark “Not supplied” and request the missing inference boundary. Do not turn summarized readings, expired calibration, or an untested hypothesis into a final product or cause conclusion. Review: the quality owner and any required specialist.
- Prohibited inference or action
- For Prohibited inference or action, state the narrow inference the evidence permits and the adjacent conclusion it does not permit, keeping observation, measurement validity, cause, and disposition separate. No “Evaluate measurement evidence” source fact supplies it; mark “Not supplied” and request the missing inference boundary. Never turn summarized readings, expired calibration, or an untested hypothesis into a final product or cause conclusion. Keep pending for the quality owner and any required specialist.
- Reviewer
- Name the authorized role that must review or decide, then show the decision as pending unless an authorized record is supplied for Reviewer. Evidence: no direct “Evaluate measurement evidence” source fact; mark “Not supplied” when absent. Do not invent a person's name, infer authority from job title, or record approval from silence. Escalate to the quality owner and any required specialist.
- Status
- Status: Select a truthful state—draft, open, blocked, pending review, or not supplied—and tie it to the evidence still required. Cite M03-I04 (F07); if insufficient, mark “Not supplied” and name the missing state control. Do not mark complete, accepted, verified, distributed, or closed without the corresponding record. Review: the quality owner and any required specialist.